Emergency lighting systems for various requirements.
When safety must function, the right system counts.
Whether individual luminaires, smaller building areas or complex system structures: different supply concepts for safety and emergency exit luminaires are suitable depending on the project.
One property.
The right supply for every area.
Overall property
One property. Three supply concepts.
Three logistics halls, each with three virtual fire compartments of 1,600 m² each. The two-story administration building is located at the front.
Up to 6 circuits
14,400 m² hall area
2 administration floors
Administration | Wireless
Own battery. Jointly monitored.
The wireless monitoring system is located in the administration’s technical room. A mesh connects the single battery luminaires with each other and with the system – across both floors.
Single battery in each luminaire
Wireless mesh for status and tests
Mains supply on site
Halls 1 + 2 | Central battery
One battery room. Six areas.
A common central battery system in a separate battery room supplies Hall 1 and Hall 2. The E30 cables run in the floor to a junction box in each virtual fire compartment. From the box, the luminaires are supplied via normal supply lines without E30.
1 central system
6 × 1,600 m²
E30 in the floor · 6 junction boxes
Hall 3 | Group battery
Each area supplies itself locally.
In each of the three virtual fire compartments, there is a separate group battery system. The luminaires are wired within their area – in this example, without E30.
3 group battery systems
1 system per 1,600 m²
Local wiring without E30
One point of contact.
Everything taken care of.
From planning and installation to ongoing maintenance and documentation, we bundle all services related to your systems. This way, you avoid unnecessary coordination and ensure your system is permanently and safely managed – standard-compliant and legally secure.
Current analysis
Lighting planning
Production
Logistics
Installation
Final acceptance & maintenance
Compare our system solutions
Homeier RaySalu Control LPS24
For fire compartments, smaller and medium-sized buildings.
Addressable 24V central battery control unit with 5″ touch display, 6 circuits, 1 h / 3 h autonomy (delivery without battery)
18 A
6 x 3 A
1 h / 3 h
Homeier RaySalu Control CPS230
For large buildings, industry, logistics and administration.
1.200
50 A
IP20
Homeier RaySalu Control EB-Mesh
For existing buildings, renovation and distributed buildings.
Single battery with wireless mesh monitoring, up to 99 luminaires
99
868 MHz
AC 120-240 V
Homeier RaySalu Control EB-Wired
For new construction and buildings with prepared infrastructure.
64-256
254
AC 120-240 V
| Article |
|
|
Downloads |
|---|---|---|---|
| Homeier RaySalu Control LPS24 1H 06X20Art. no. HRS-CTL-LPS24-1H-06X20 · LPS24 · AC 120-240 V | 06x20 | LPS24V (local battery 24VDC) | |
| Homeier RaySalu Control LPS24 3H 06X20Art. no. HRS-CTL-LPS24-3H-06X20 · LPS24 · AC 120-240 V | 06x20 | LPS24V (local battery 24VDC) | |
| Homeier RaySalu Control CPS230 12x20Art. no. HRS-CTL-CPS230-12X20 · CPS230 · AC 120-240 V | 12x20 | CPS230V (central battery 230VAC) | |
| Homeier RaySalu Control CPS230 24x20Art. no. HRS-CTL-CPS230-24X20 · CPS230 · AC 120-240 V | 24x20 | CPS230V (central battery 230VAC) | |
| Homeier RaySalu Control CPS230 44x20Art. no. HRS-CTL-CPS230-44X20 · CPS230 · AC 120-240 V | 44x20 | CPS230V (central battery 230VAC) | |
| Homeier RaySalu Control CPS230 72X20Art. no. HRS-CTL-CPS230-72X20 · CPS230 · AC 120-240 V | 72x20 | CPS230V (central battery 230VAC) | |
| Homeier RaySalu Control CPS230 SUB 16x20Art. no. HRS-CTL-CPS230-SUB-16X20 · CPS230 · AC 120-240 V | 16x20 | CPS230V (central battery 230VAC) | |
| Homeier RaySalu Control EBM 01X100Art. no. HRS-CTL-EBM-01X100 · AC 120-240 V | 01X100 | EBM (single battery with wireless mesh network) | |
| Homeier RaySalu Control EBW 01X64Art. no. HRS-CTL-EBW-01X64 · AC 120-240 V | 01X64 | EBW (single battery with cable interconnection) | |
| Homeier RaySalu Control EBW 02X64Art. no. HRS-CTL-EBW-02X64 · AC 120-240 V | 02X64 | EBW (single battery with cable interconnection) | |
| Homeier RaySalu Control EBW 03X64Art. no. HRS-CTL-EBW-03X64 · AC 120-240 V | 03X64 | EBW (single battery with cable interconnection) | |
| Homeier RaySalu Control EBW 04X64Art. no. HRS-CTL-EBW-04X64 · AC 120-240 V | 04X64 | EBW (single battery with cable interconnection) |
Safe orientation begins with the right lighting.
Safety luminaires ensure that escape and rescue routes remain reliably illuminated even during a power failure. Depending on the area of application, various designs and solutions are available for indoor spaces, industry, logistics, outdoor areas and Tri-proof areas.
Visible safety on every escape route
Emergency exit signs clearly mark escape and rescue routes and ensure that exits and changes of direction are quickly recognized. Different designs and mounting types enable a suitable solution for a wide variety of buildings and areas of use.
Find the right emergency lighting system together.
Together, we select the system solution that fits your project’s building size, infrastructure and requirements.
Find the right emergency lighting system together.
Together, we select the system solution that fits your project’s building size, infrastructure and requirements.